The Annual Occupational Radiation Dosimetry Report provides information to understand the dose quantities being reported. For general information about radiation exposure, please refer to www.radiationanswers.org. The adjacent information is available to download in the Annual Occupational Radiation Dosimetry Report (pdf).

Annual Occupational Radiation Dosimetry Report
Annual Occupational Radiation Dosimetry Report
Radiation exposure and dose quantities
Title 10 Code of Federal Regulation Part 835, Occupational Radiation Protection (10 CFR 835), requires assessment, recording and reporting of radiation doses to individuals who are exposed to sources of radiation or radioactive contamination. This includes assessing external exposure from a variety of radiation types, such as, beta, photon, and neutron radiation. External exposures may be uniform over the whole body or occur in a non-uniform (i.e., limited body location) fashion. Internal doses occur when radioactive material is taken into the body through ingestion, inhalation, absorption or wounds. The requirements include assessing doses to the whole body, skin, lens of the eyes, extremities and various organs and tissues.
In June 2007, 10 CFR 835 was amended to adopt more current dosimetric models (e.g., International Commission on Radiological Protection Publication 60 (ICRP 60)). Adoption of ICRP 60 dosimetric models included the updating of tissue weighting factors used primarily for assessing radiation doses resulting from intakes of radioactive material. A change in ICRP 60 includes the addition of skin as a specified organ assigned a tissue weighting factor. Prior to the 2007 amendment to 10 CFR 835, skin was not listed as an organ specifically assigned a tissue weighting factor. Other changes to 10 CFR 835 included modification to the magnitude and definition of radiation weighting factors (formerly Quality Factors) which primarily affects neutron dose calculations.
Furthermore, the June 2007 amendment to 10 CFR 835 included a change to the naming convention for dose quantities. Sections 702 and 801 of 10 CFR 835 specify the radiological dose quantities which must be reported annually to monitored individuals. Los Alamos National Laboratory, in accordance with its DOE-approved implementation plan for the amended 10 CFR 835, began reporting dose quantities consistent with the prescribed changes beginning with calendar year 2008 dose results.
The table below describes how the various components of measured and assessed dose quantities are compiled into the results shown on the Annual Occupational Radiation Dosimetry Report.
Radiation Reporting Quantities
Quantity to Record | Components of Quantity |
Effective dose from external sources (ED)* | Sum of:
Measured from whole body dosimetry. |
Equivalent dose to lens of eye from external sources | Sum of:
Lens of eye dose is normally derived from whole body dosimetry unless supplemental dosimetry is provided for direct monitoring of the lens of the eye. |
Equivalent dose to skin | Sum of:
|
Equivalent dose to any extremity Note: Upper Left and Right extremities are hands and arms below the elbows. Lower Left and Right extremities are feet and legs below the knees. | Sum of:
Constraints are imposed such that no extremity doses are reported to be less than the equivalent dose to the skin. |
Committed effective dose (CED) | Committed effective dose from the intakes of radionuclides. (Effective dose received over a 50 year period from intake.) |
Total effective dose (TED) | Sum of:
|
Committed equivalent dose to any organ or tissue Note: Only organ and tissue doses greater than 1 rem are shown on this report. | Committed equivalent dose to any organ/tissue from the intake of radionuclides. (Equivalent dose received over a 50 year period from intake.) |
Total Organ/Tissue dose (except skin) Note: Refer to the quantity Equivalent dose to the skin for the appropriate skin value. | Sum of:
|
Cumulative total effective dose (CTED) | Sum of:
|
Equivalent dose to the embryo/fetus Note: Only reported for declared pregnant workers. | Sum of:
|
* Effective Dose from external sources (ED) is set equal to the Equivalent Dose to the whole body from external sources as accepted within 10 CFR 835 (2007).
** Pre-10 CFR 835 (2007) quantity, total effective dose equivalent (TEDE), as recorded prior to 2008.
All dose quantities may additionally include results of special dose investigations.
If you have any questions on these quantities or your AORD report, please email dosimetry_questions@lanl.gov.