University of California,
Irvine Bridge column Tests Overview: The University of California, Irvine (UCI) has a research contract with CALTRANS to perform static, cyclic load tests on seismically retrofitted, reinforced-concrete bridge columns. This project is under the direction of Professor Gerry Pardoen at UCI (gpardoen@e4e.oac.uci.edu) and Mr. Tim Leahy (tleahy@trmx2.dot.ca.gov) at CALTRANS. The primary purpose of these tests is to study the relative strength and ductility provided by two retrofit construction procedures. The first procedure extends the diameter of the existing column with cast-in-place concrete. The second procedure extends the diameter of the existing column using shotcrete that is sprayed onto the exterior of the existing column. With funds obtained through Los Alamos National Laboratory’s (LANL) University of California interaction office, staff from the LANL’s Engineering Analysis Group and a faculty member from the Mechanical Engineering Department at Rose-Hulman Institute of Technology were able to perform experimental modal analyses on the columns. These modal tests were performed at various stages during the static load cycle testing. Results obtained from the experimental modal analyses provide further insight into the relative effectiveness of the two retrofit procedures. In addition, data form these modal tests were analyzed
with various parametric and non-parametric damage identification algorithms.
From a damage identification standpoint one of the unique features of
these tests was the ability to examine the effects of column pre-load
on the damage identification process with varying amounts of damage input
to the structure in a controlled and quantified manner. Also, the concrete
column tests provided these investigators’ with their first experience
in applying damage identification algorithms to reinforced concrete structures.
The data from these tests are provided on this web
site for others to analyze. Also, provided on this site are the ABAQUS
input files for the accompanying finite element analyses. A description
of the structures, the testing and results obtained is given below. Test Structure Description
The test structures consisted of two 24-in-dia
(61-cm-dia) concrete bridge columns that were subsequently retrofitted
to 36-in-dia (91-cm-dia) columns. The first column tested, labeled Column
3, was retrofitted by placing forms around existing column and placing
additional concrete within the form. The second column, labeled Column
2, was extended to the 36-in-diameter by spraying concrete in a process
referred to as shotcreting. The shotcreted column was then finished with
a trowel to obtain the circular cross-section. The 36-in-dia. portions of both columns were
136 in. (345 cm) in length. The columns were cast on top of 56-in-sq.
(142-cm-sq.) concrete foundation that was 25-in-high (63.5-cm-high).
A 24-in-sq. concrete block that had been cast integrally with the column
extends 18-in. above the top of the 36-in-dia. portion of the column.
This block was used to attach the hydraulic actuator to the columns for
static cyclic testing and to attach the electro-magnetic shaker used for
the experimental modal analyses. As is typical of actual retrofits in
the field, a 1.5-in-gap (3.8-cm-gap) was left between the top of the foundation
and the bottom of retrofit jacket. Therefore, the longitudinal reinforcement
in the retrofitted portion of the column did not extend into the foundation.
The concrete foundation was bolted to the 2-ft-thick (0.61-m-thick) testing
floor in the UCI laboratory during both the static cyclic tests and the
experimental modal analyses. The structures were not moved once testing
was initiated. Figure 1 shows the test structure geometry. The columns were constructed by first placing the foundations on July 18th, 1997. Then the 24-in-diameter columns were placed on August 19th and the retrofits were added on September 19th. Corresponding portions of both test structures were constructed from the same batch of concrete. The only measured material property for these columns was the 28-day ultimate strength of the concrete and the test day ultimate strength. The 28-day ultimate strength of foundations was 4600 psi (32 MPa). Test day ultimate strength was
Fig. 1 Column Dimensions not measured for the foundations. The 24-in-dia. column 28-day ultimate strength was 4300 psi (30 MPa) and the test day ultimate strength was 4800 psi (33 MPa). The 28-day-ultimate strength of the retrofit portion of the structures was 5200 psi (36 MPa). On test day the strength of the retrofit concrete was found to be 4900 psi (34 MPa). Within the 24-in-dia initial column reinforcement consisted of an inner circle of 10 #6 (3/4-in-dia, 19-mm-dia) longitudinal rebars with a yield strength of 74.9 ksi (516 MPa). These bars were enclosed by a spiral cage of #2 (1/4-in-dia, 13.5-mm-dia) rebar having a yield strength of 30 ksi (207 MPa) and spaced at a 7-in pitch (18 cm). Two-inch-cover (5- cm-cover) was provided for the spiral reinforcement. The retrofit jacket had 16 #8 (1-in-dia, 25-mm-dia) longitudinal rebars with a yield strength of 60 ksi (414 MPa). These bars were enclosed by a spiral cage of #6 rebar spaced at a 6-in pitch (15 cm). The spiral steel also had a yield strength of 60 ksi. Again, 2-in.-cover was provided for this reinforcement. Lap-splices 17-in (43-cm) in length were used to connect the longitudinal reinforcement of the existing 24-in column to the foundation. STATIC LOADINGPrior to applying lateral loads, an axial
load of 90 kips (400 kN) was applied to simulate dead loads that an actual
column would experience. A steel beam was placed on top of the column.
Vertical steel rods, fastened to the laboratory floor, were tensioned
by jacking against the steel beam that, in turn, applied a compressive
load to the column. A photo of the test configuration is shown in Fig.
2.
Fig. 2 Test Configuration. An hydraulic actuator was used to apply lateral
load to the top of the column in a cyclic manner. The loads were first
applied in a force-controlled manner to produce lateral deformations at
the top of the column corresponding to 0.25DyT, 0.5DyT,
0.75DyT and DyT. Here DyT
is the lateral deformation at the top of the column corresponding to the
theoretical first yield of the longitudinal reinforcement. The reader
is referred to http:\\www.ics.uci.edu./~athomas/caltrans for a more detailed
summary of the calculation of the deformation corresponding to first yield.
The structure was cycled three times at each of these load levels. Based on the observed response, a lateral deformation corresponding the actual first yield, Dy, was calculated and the structure was cycled three times in a displacement-controlled manner to that deformation level. Next, the loading was applied in a displacement-controlled manner, again in sets of three cycles, at displacements corresponding to 1.5Dy, 2.0Dy, 2.5Dy, etc. until the ultimate capacity of the column was reached. Load deformation curves for columns 3 and 2 are shown in Figs 3 and 4, respectively. This manner of loading put incremental and quantifiable damage into the structures. The axial load was applied during all static tests. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TABLE I Finite Element Modal Analysis Results |
||||
Continuum ModelResonant Frequencies (Hz) |
Continuum Model(with pre-load) Resonant Frequencies (Hz) |
Beam ModelResonant Frequencies (Hz) |
||
First Bending Mode |
19.1 |
19.1 |
25.6 |
|
|
First Torsion Mode |
114. |
114. |
131. |
|
|
Second Bending Mode |
124. |
124. |
136. |
|
|
First Axial Mode |
181. |
181. |
204. |
|
|
Third Bending Mode |
306. |
306. |
319. |
|
|
Second torsion Mode |
351. |
351. |
389. |
|

Fig. 8 Undeformed Mesh of the continuum model.

Fig. 9. (A) First bending mode and (B) first torsion
mode calculated with the continuum model.

Fig. 10. (A) Second bending mode and (B) first axial mode calculated with the
continuum model.

Fig. 11. (A) Third bending mode and (B) second torsion mode calculated with
the continuum model.

Fig. 12. (A) First bending mode, (B) second bending mode, and (C) third bending
mode calculated with the beam model.
Table II summarizes the modal properties (resonant
frequencies and modal damping values) that were obtained from applying
a rational-fraction polynomial curve-fit algorithm in the DIAMOND experimental
modal analysis/damage ID code to the measured FRFs. Compare undamaged,
no pre-load results for both columns to FEM results. Compare pre-load
to no pre-load results for undamaged columns. Compare results at various
damage levels for both columns. Make conclusion on how similar the columns
are based on these measures.
TABLE IIExperimental Modal Analysis Results |
|||||||
|
First Bending Mode Freq. (Hz)/ Damp.(%) |
First Torsion Mode Freq.(Hz)/ Damp. (%) |
Second Bending Mode Freq. (Hz)/ Damp.(%) |
First Axial Mode Freq.(Hz)/ Damp. (%) |
Third Bending Mode Freq. (Hz)/ Damp.(%) |
Second Torsion Mode Freq.(Hz)/ Damp. (%) |
||
|
Finite Element Continuum Model |
19.1/ - |
114/ - |
124/ - |
181/ - |
306/ - |
351/ - |
|
|
Finite Element Beam Model |
25.6/ - |
131/ - |
136/ - |
204/ - |
319/ - |
389/ - |
|
|
Column 3, No pre-load, undamaged Test0 |
|||||||
|
Column 2, No pre-load, undamaged Test 6 |
|||||||
|
Column 3, With Pre-load, Undamaged Test0P |
|||||||
|
Column 2, With Pre-load,
Undamaged Test6P |
|||||||
|
Column 3, No pre-load, DyT Test1 |
|||||||
|
Column 2, No pre-load, DyT Test7 |
|
||||||
|
Column 3, With Pre-load, DyT Test1P |
|||||||
|
Column 2, With Pre-load, DyT Test7P
|
|
||||||
|
Column 3, No pre-load, 1.5Dy Test2 |
|||||||
|
Column 2, No pre-load, 1.5Dy Test8 |
|||||||
|
Column 3, With Pre-load, 1.5Dy Test2P |
|||||||
|
Column 2, With Pre-load, 1.5Dy Test8P |
|||||||
|
Column 3, No pre-load, 2.5Dy Test3 |
|||||||
|
Column 2, No pre-load, 2.5Dy Test9 |
|||||||
|
Column 3, With Pre-load, 2.5Dy Test3P |
|||||||
|
Column 2, With Pre-load, 2.5Dy Test9P |
|||||||
|
Column 3, No pre-load, 4.0Dy Test4 |
|||||||
|
Column 2, No pre-load, 4.0Dy Test10 |
|||||||
|
Column 3, With Pre-load, 4.0Dy Test4P |
|||||||
|
Column 2, With Pre-load, 4.0Dy Test10P |
|||||||
|
Column 3, No pre-load, 7.0Dy Test5 |
|||||||
|
Column 2, No pre-load, 7.0Dy Test11 |
|||||||
|
Column 3, With Pre-load, 7.0Dy Test5P |
|||||||
|
Column 2, With Pre-load, 7.0Dy Test11P |
|||||||
FRFs: Overlay magnitude from Channels 19,
20, 21 for all damage levels, respectively. Compare pre-load to no pre-load.
Overlay same channels from different columns for each damage level. Overlay
linearity check results
Mode shapes: Show 3 bending, 3 torsion, axial,
shows torsion change for each damage level. Other modes? Compare two
columns, pre-load to no pre-load.
Coherence: Compare coherence for different
sensitivity accels. (Ch 19 and 40) (Ch23 and 4) (Ch 20 and 35) Compare
coherences to input power spectrum. Compare pre-load to no pre-load.
Damage Detection (to come)
Flexibility analysis (to come)
Model updating analysis (to some)
Non-parametric analysis (to come)